Bore size(mm) | 16 | 20; 25; 32; 40 | 50; 63 | |
Acting type | MSA/MTA | Single acting | Single acting | - |
MA/MAD/MAJ | Double acting | Double acting | - | |
MAR | - | Double acting | Double acting | |
MAC/MACD/MACJ | Double acting with cushion | Double acting with cushion | Double acting with cushion | |
Fluid | Air(to be filtered by 40um filter element) | Air(to be filtered by 40um filter element) | Air(to be filtered by 40um filter element) | |
Operating pressure | Double acting | 0.15-1.0MPa(22-145psi)(1.5-10.0bar) | 0.15-1.0MPa(22-145psi)(1.5-10.0bar) | 0.15-1.0MPa(22-145psi)(1.5-10.0bar) |
Single acting | 0.2-1.0MPa(28-145psi)(2.0-10.0bar) | 0.2-1.0MPa(28-145psi)(2.0-10.0bar) | 0.2-1.0MPa(28-145psi)(2.0-10.0bar) | |
Proof pressure | 1.5MPa(215psi)(15bar) | 1.5MPa(215psi)(15bar) | 1.5MPa(215psi)(15bar) | |
Temperature ℃ | -20-70 | -20-70 | -20-70 | |
Speed range mm/s | Double acting : 30-800 Single acting:50-800 | Double acting : 30-800 Single acting:50-800 | Double acting : 30-800 Single acting:50-800 | |
Stroke tolerance | 0-150(0-+1.0) >150(0-+1.5) | 0-150(0-+1.0) >150(0-+1.5) | 0-150(0-+1.0) >150(0-+1.5) | |
Cushion type | Variable cushion | Variable cushion | Variable cushion | |
Adjustable cushion stroke | MAC/MACD/MACJ Series: Variable cushion: Other series: Bumper | MAC/MACD/MACJ Series: Variable cushion: Other series: Bumper | MAC/MACD/MACJ Series: Variable cushion: Other series: Bumper | |
Port size | M5x0.8 | 1/8" | 1/4" |
MA | 20 | X | 50 | S | CM | ||||
MAD | 20 | X | 50 | S | |||||
MAJ | 20 | X | 50 | - | 20 | S | |||
MAR | U | 20 | X | 50 | S | ||||
Model | Front cover | Bore size | Stroke | Adjustable St. | Magnet | Back cover | Mounting type | ||
MA:Mini cylinder(Double acting) MAC:Mini cylinder(Double acting with cushion) MSA: Mini cylinder (Single acting_push) MTA: Mini cylinder (Single acting_pull) | - | Model | Bore size | Refer to stroke table for details | - | S: With magnet | CA: Pivot type U: Flat-end type CM: Round-end type | Blank: No accessories FA: FA type SDB: SDB type LB: LB type | |
MA:Mini cylinder(Double acting) MAC:Mini cylinder(Double acting with cushion) MSA: Mini cylinder (Single acting_push) MTA: Mini cylinder (Single acting_pull) | - | MA MSA MTA MAD MAJ | 16 20 25 32 40 | - | CA: Pivot type U: Flat-end type CM: Round-end type | Blank: No accessories FA: FA type SDB: SDB type LB: LB type | |||
MAD:Mini cylinder(Double rod) MACD: Mini cylinder(Double rod with cushion) | - | MA MSA MTA MAD MAJ | 16 20 25 32 40 | - | - | Blank: No accessories FA: FA type LB: LB type | |||
MAJ: Mini cylinder (Adjustable stroke) MACJ: Mini cylinder (Adjustable stroke with cushion) | - | MAC MACD MACJ | 16 | 10 20 30 40 50 75 100 | - | Blank: No accessories FA: FA type LB: LB type | |||
MAJ: Mini cylinder (Adjustable stroke) MACJ: Mini cylinder (Adjustable stroke with cushion) | - | MAC MAR MACD MACJ | 20 25 32 40 50 63 | 10 20 30 40 50 75 100 | - | Blank: No accessories FA: FA type LB: LB type | |||
MAR: Mini Cylinder (Double acting with cushion) | F: Front mounting U:Up mounting | MAC MAR MACD MACJ | 20 25 32 40 50 63 | - | - | - |
1.When load changes in the work, the cylinder with abundant output capacity shall be selected.
2. Relative cylinder with high temperature resistance or corrosion resistance shall be chosen under the condition of high temperature or corrosion.
3. Necessary protection measure shall be taken in the environment with higher humidity, much dust or water drops, oil dust and welding dregs.
4.Dirty substances in the pipe must be eliminated before cylinder is connected with pipeline to prevent the entrance of particles into the cylinder.
5. The medium used by cylinder shall be filtered to 40μm or below.
6.Anti-freezing measure shall be adopted under low temperature environment to prevent moisture freezing.
7. The cylinder shall be carried out test run without load before
application. Prior to run, buffer shall be turned to the minimum and gradually released to avoid the damage on cyllinder caused by excessive impact.
8. To avoid side load, otherwise, piston rod will be bent and deformed and damage the thread at the end of the rod. Single-acting type can not be added in return.
9. If the cyllinder is dismantled and stored for a long time, please to conduct anti-rust treatment to the surface. Anti-dust caps shall be added in air inlet and outlet ports. The front and back cover can not be dismantled, which shall be especially noticed.