MA Series

1.Standard cylinder manufactured by our enterprise.
2.Piston adopts heterogeneous twoway seal structure. It has compact size and has the function of grease reservation.
3.Front cover has fixed bumper which can reduce the impact of direction change of the cylinder.
4.There are several modes of back cover which makes the installation of cylinder more convenient.
5.Front and back cover and stainless steel block adopt riveted rolling packed structure to form a reliable connection.
6.The cylinder body has stainless steel pipes with high precision to produce high strength and corrosion resistance.
7.There are cylinders and mounting accessories with several specifications for your choice.
8.All cylinders of this series have magnet.

Specification

Bore size(mm)1620; 25; 32; 4050; 63
Acting typeMSA/MTASingle actingSingle acting-
MA/MAD/MAJDouble actingDouble acting-
MAR-Double actingDouble acting
MAC/MACD/MACJDouble acting with cushionDouble acting with cushionDouble acting with cushion
FluidAir(to be filtered by 40um filter element)Air(to be filtered by 40um filter element)Air(to be filtered by 40um filter element)
Operating pressureDouble acting0.15-1.0MPa(22-145psi)(1.5-10.0bar)0.15-1.0MPa(22-145psi)(1.5-10.0bar)0.15-1.0MPa(22-145psi)(1.5-10.0bar)
Single acting0.2-1.0MPa(28-145psi)(2.0-10.0bar)0.2-1.0MPa(28-145psi)(2.0-10.0bar)0.2-1.0MPa(28-145psi)(2.0-10.0bar)
Proof pressure1.5MPa(215psi)(15bar)1.5MPa(215psi)(15bar)1.5MPa(215psi)(15bar)
Temperature ℃-20-70-20-70-20-70
Speed range mm/sDouble acting : 30-800 Single acting:50-800Double acting : 30-800 Single acting:50-800Double acting : 30-800 Single acting:50-800
Stroke tolerance0-150(0-+1.0) >150(0-+1.5)0-150(0-+1.0) >150(0-+1.5)0-150(0-+1.0) >150(0-+1.5)
Cushion typeVariable cushionVariable cushionVariable cushion
Adjustable cushion strokeMAC/MACD/MACJ Series: Variable cushion: Other series: BumperMAC/MACD/MACJ Series: Variable cushion: Other series: BumperMAC/MACD/MACJ Series: Variable cushion: Other series: Bumper
Port sizeM5x0.81/8"1/4"

Order Code

MA20X50SCM
MAD20X50S
MAJ20X50-20S
MARU20X50S
ModelFront coverBore sizeStrokeAdjustable St.MagnetBack coverMounting type
MA:Mini cylinder(Double acting)
MAC:Mini cylinder(Double acting with cushion)
MSA: Mini cylinder (Single acting_push)
MTA: Mini cylinder (Single acting_pull)
-ModelBore sizeRefer
to
stroke
table
for
details
-S: With
magnet
CA: Pivot type
U: Flat-end type
CM: Round-end
type
Blank: No accessories
FA: FA type
SDB: SDB type
LB: LB type
MA:Mini cylinder(Double acting)
MAC:Mini cylinder(Double acting with cushion)
MSA: Mini cylinder (Single acting_push)
MTA: Mini cylinder (Single acting_pull)
-MA
MSA
MTA
MAD
MAJ
16
20
25
32
40
-CA: Pivot type
U: Flat-end type
CM: Round-end
type
Blank: No accessories
FA: FA type
SDB: SDB type
LB: LB type
MAD:Mini cylinder(Double rod)
MACD: Mini cylinder(Double rod with cushion)
-MA
MSA
MTA
MAD
MAJ
16
20
25
32
40
--Blank: No accessories
FA: FA type
LB: LB type
MAJ: Mini cylinder (Adjustable stroke)
MACJ: Mini cylinder (Adjustable stroke with cushion)
-MAC
MACD
MACJ
1610 20
30 40
50 75 100
-Blank: No accessories
FA: FA type
LB: LB type
MAJ: Mini cylinder (Adjustable stroke)
MACJ: Mini cylinder (Adjustable stroke with cushion)
-MAC
MAR
MACD
MACJ
20
25
32
40
50
63
10 20
30 40
50 75 100
-Blank: No accessories
FA: FA type
LB: LB type
MAR: Mini Cylinder
(Double acting with cushion)
F: Front mounting
U:Up mounting
MAC
MAR
MACD
MACJ
20
25
32
40
50
63
---

Installation & Usage

1.When load changes in the work, the cylinder with abundant output capacity shall be selected.
2. Relative cylinder with high temperature resistance or corrosion resistance shall be chosen under the condition of high temperature or corrosion.
3. Necessary protection measure shall be taken in the environment with higher humidity, much dust or water drops, oil dust and welding dregs.
4.Dirty substances in the pipe must be eliminated before cylinder is connected with pipeline to prevent the entrance of particles into the cylinder.
5. The medium used by cylinder shall be filtered to 40μm or below.
6.Anti-freezing measure shall be adopted under low temperature environment to prevent moisture freezing.
7. The cylinder shall be carried out test run without load before
application. Prior to run, buffer shall be turned to the minimum and gradually released to avoid the damage on cyllinder caused by excessive impact.
8. To avoid side load, otherwise, piston rod will be bent and deformed and damage the thread at the end of the rod. Single-acting type can not be added in return.
9. If the cyllinder is dismantled and stored for a long time, please to conduct anti-rust treatment to the surface. Anti-dust caps shall be added in air inlet and outlet ports. The front and back cover can not be dismantled, which shall be especially noticed.

MOGO Pneumatic

No. 2-1 Tongzhou Road, Jishan Industrial Park, Xikou Town, Fenghua District, Ningbo City, Zhejiang Province, China
Copyright © 2025 mogo pneumatic. All Rights Reserved
linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram